3-30 Ringing in Series II peripherals
297-1001-131 Standard 06.01 October 2000
Note:
It is necessary to busy the unit so that the mate unit enters a
takeover.
11 To post the second LCM in the frame or cabinet, type
> POST LCM 0 1
and press the Enter key.
Example of a MAP display:
12 Are the units in the LCM aligned to use RG-0?
13 To get an LCM unit to use RG-0, type
> SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number you want to switch to RG-0 (0 or 1)
Example of a MAP display:
swrg unit 0
LCM HOST 00 1 Unit 0 SWRG Passed
If both LCM units Do
are aligned and both use RG-0 step 14
are not aligned or both do not
use RG-0
step 13
SysB ManB OffL CBsy ISTb InSv
PM 0 0 0 0 3 39
LCM 0 0 0 0 0 4
LCM HOST 00 0 InSv Links_OOS: CSide 0 , PSide 0
Unit0: InSv Takeover /RG: 0
Unit1: ManB /RG: 0
11 11 11 11 11 RG: Pref 1 InSv
Drwr: 01 23 45 67 89 10 23 45 67 89 Stby 0 InSv
.. .. .. .. .. .. .. .. .. ..
bsy unit 1
LCM HOST 00 1 Unit 1 Bsy Passed
SysB ManB OffL CBsy ISTb InSv
PM 0 0 0 0 3 39
LCM 0 0 0 0 0 4
LCM HOST 00 1 InSv Links_OOS: CSide 0 , PSide 0
Unit0: InSv /RG: 1
Unit1: InSv /RG: 1
11 11 11 11 11 RG: Pref 0 InSv
Drwr: 01 23 45 67 89 10 23 45 67 89 Stby 1 InSv
.. .. .. .. .. .. .. .. ..
..
Both units use ringing generator 1 (RG-1).