Universal Remote DMS-100 Especificações Página 105

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 104
Ringing in Series II peripherals 3-37
DMS-100 Ringing System
46 To test the LCM units, type
> POST LCM 0 0
and press the Enter key.
> TST UNIT 0
and press the Enter key.
> POST LCM 0 1
and press the Enter key.
> TST UNIT 0
and press the Enter key.
Note:
This step tests the ringing generators.
47 You completed this procedure.
Single LCM configuration
This procedure describes how to reconfigure the ringing generators in
peripheral modules (PM) in a single LCM configuration. The procedure begins
with the reconfiguration of ringing generator 1 and then reconfigures ringing
generator 0. For the following procedure, the LCM site is RLCM. The frame
number is 0. The unit number for the LCM is 0. These values are for example
only. Operating company personnel should use site, frame, and unit values for
the affected single LCM PMs.
Perform this procedure during a period of low traffic. In the unlikely event that
something happens and obstructs the ringing system, back out of the procedure
by reversing the steps you entered. If a serious problem exists, such as an E1
outage, immediately contact Emergency Technical Assistance Support
(ETAS).
Vista de página 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 133 134

Comentários a estes Manuais

Sem comentários