Universal Remote DMS-100 Especificações Página 85

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 84
Ringing in Series II peripherals 3-17
DMS-100 Ringing System
Detailed ringing schematic
The schematic in theFigure 3-6, "Detailed ringing schematic" on page 3-18
shows the signal path from the ringing generators to the line drawers located
in both units of the LCM. This signal path includes the NT6X53AA power
converters in both LCM units and the NT6X54AA BICs in the line drawers.
The schematic shows ringing generator outputs to only one LCM for clarity;
the outputs shown in this figure connect to both LCMs in the LCE. Also, only
two BICs are shown in the schematic; however, the connections are actually
made to the BIC in each of the 10 line drawers in the LCM.
As illustrated by the detailed schematic, the ringing generator provides two
important functions. The ringing generator generates both ringing signals and
ANI/coin signals. These functions are described next.