Ringing in Series II peripherals 3-27
DMS-100 Ringing System
Figure 3-9 Summary of Dual LCM ringing generator configuration change procedure
This flowchart provides a
summary of the procedure.
Use the instructions in the
step-action procedure that
follows this flowchart to
perform the procedure.
Check the
configurationin
table LCMINV
Post the LCM
units
Do you need
to switch RGs
to the RG you
do not want to
power down?
Use SWRG to
get both units on
the correct RG
Change the original
tuple to the desired
RNGTYPE
Busy the LCM
units
Perform
changes to the
RG
Perform a
NILCHANGE on
the other LCM
Post and RTS
the LCM units
Repeat this
procedure for
the other RG
Change the
RNGTYPE to
unassigned in
table LCMINV
Perform a
NILCHANGE on
the other LCM
You completed
this procedure
YY
NN
TST the LCM
units