Ringing in Series I peripherals 2-9
DMS-100 Family DMS-100 Ringing System BASE15 and up
Ringing generator takeover and take back
Both ringing generators in each bay provide ringing signals for the lines in the
LM or RLM bay. The signal processor and RGI program the ringing generators
and, through the ring multiplexer, connect each ringing generator output to the
appropriate line. If either ring generator fails, the SP/RGI restricts ringing to
the alternate RG. The ringing system can still function in this configuration.
However, the ringing capacity in the affected bay is reduced.
LM and RLM ringing generator parameters
The NT2X05 power converter +24 V card used in the LM or RLM as the
ringing generator has the following operating parameters:
Table 2-1 LM/RLM ringing generator parameters
Parameter Value
Frequency (programmable range) 0 to 67Hz
Maximum current 350 mA
Overvoltage shutbacks Over 165 V for more than 1.5 seconds
Voltage detect +/-20 V nominal
Current detect +/-10 mA nominal
Overcurrent shutback +/-350 mA nominal