3-40 Ringing in Series II peripherals
297-1001-131 Standard 06.01 October 2000
7 Are the units in the LCM aligned to use RG-0?
8 To get an LCM unit to use RG-0, type
> SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number you want to switch to RG-0 (0 or 1)
Example of a MAP responce:
swrg unit 1
LCM RLCM 00 0 Unit 1 SWRG Passed
Note:
Perform this step for each LCM unit that needs to use RG-0.
9 To busy unit 1 of the LCM, type
> BSY UNIT 1
and press the Enter key.
If both LCM units Do
are aligned and both use RG-0 Step 9
are not aligned or both do not
use RG-0
Step 8
SysB ManB OffL CBsy ISTb InSv
PM 0 0 0 0 3 18
LCM 0 0 0 0 1 0
LCM RLCM 00 0 InSv Links_OOS: CSide 0 , PSide 0
Unit0: InSv /RG: 0
Unit1: InSv /RG: 0
11 11 11 11 11 RG: Pref 0 InSv
Drwr: 01 23 45 67 89 10 23 45 67 89 Stby 1 InSv
.. .. .. .. .. .. .. .. ..
..
Both units use ringing generator 0 (RG-0).