5-6 Ringing system maintenance
297-1001-131 Standard 06.01 October 2000
Ringing generator alarms
When a failure occurs in a ringing generator, an alarm is posted under the PM
header of the MAP display, unless a higher level alarm already exists, in which
case the higher level alarm is displayed.
Replacing ring generators
Replacing a faulty ringing generator or replacing a ringing generator for
verification purposes is described in Card Replacement Procedures.
When you replace a ringing generator in an LCM or RLCM, you must ensure
that the DIP switch settings on the replacement generator correspond to the
ringing type assigned to the PM. A description of the switch settings is
available in the Hardware Description Manual.
Ringing maintenance and troubleshooting
Problems in the DMS-100 ringing system can be isolated using the DMS-100
MAP. At the PM level, the ringing system circuit cards can be made offline and
tested. At the line test position, tests, including a ringing test, can be performed
on subscriber lines. The loop resistance and capacitance of subscriber lines
also can be measured from the LTP level.
Note: A troubleshooting procedure for isolating ringing problems is
located in the Peripheral Modules Maintenance Guide and covers situations
where a loss of ringing is experienced.
PM Type: LCM Int. No.: 2 Status index: 0 Node_No: 36
Memory Size - Unit 0: 256K , Unit 1: 256K
Loadnames: LCMINV - BBB , Unit0: XLCM05AK, Unit1: XLCM05AK
LCM HOST 00 0 is included in the list of LCM types
scheduled for a REX test.
REX on LCM HOST 00 0 has not been performed.
Node Status: {OK, FALSE}
Unit 0 Status: {OK, FALSE} //RRGG::00
Unit 1 Status: {OK, FALSE} //RRGG::00
RRiinnggGGeenneerraattoorrSSttaattuuss::
RRGG00SSttaattuuss::{{OOKK}}PPrreeffeerrrreedd
RRGG11SSttaattuuss::{{OOKK}}SSttaannddbbyy
RRGGiinnOOvveerrllooaadd::NNoo
Site Flr RPos Bay_id Shf Description Slot EqPEC
HOST 01 C05 LCE 00 51 LCM 00 0 6X04AA
World Line Card Template(s) in use:
6X17BA 6X18BA
Services : NEUTRAL
Identifies current resource of
ringing generator and if that
ringing generator is preferred
or standby for this LCM.
Indicates if the ringing
generator is in overload.
Identifies which ringing
generator is selected.